Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title Online Turn Fault Diagnosis Method for Permanent Magnet BLDC Motor using an Overlap Control Method and 2nd Order Low Pass RC Filter
Authors Seon-Hwan Hwang ; Jin-Hyung Yoo ; Tae-Uk Jung
DOI http://dx.doi.org/10.5207/JIEIE.2019.33.1.041
Page pp.41-47
ISSN 1225-1135
Keywords Turn Fault ; Diagnosis ; Overlap Control ; Signal Analysis
Abstract Recently, BLDC motors are used in widened area because of permanent magnet manufacturing technology and drive technology are developed. The use of permanent magnets has been actively pursued for application to fields requiring high efficiency motors due to their high output relative to weight as well as high efficiency advantages over induction motors and wire wound type synchronous motors.?However, BLDC motors are not reliable in the realtime diagnosis results, so they are mainly used for diagnosis by direct measurement after decomposition. This method has the disadvantage that the accuracy is guaranteed but the diagnosis time is very long. In order to overcome these drawbacks, this paper proposes a method to diagnose turn fault by using overlap control method and 2nd order RC filter for online diagnosis of permanent magnet BLDC motor. The validity of the proposed diagnosis method is verified by analyzing the results of 2D finite element analysis.