Bi-directional inverter, DC coupling, ESS(Energy Storage System), PV converter, UPS(Uninterrupt Power Supply)

1. ์„œ ๋ก 

์˜จ๋„๋ณ€ํ™”์— ๋ฏผ๊ฐํ•œ ์ œํ’ˆ์„ ์ผ์ •ํ•œ ์˜จ๋„๋กœ ์‹ ์„ ๋„๋ฅผ ์œ ์ง€์‹œ์ผœ ๋ณด๊ด€ํ•˜๊ฑฐ๋‚˜ ์œ ํ†ตํ•˜๊ธฐ์œ„ํ•œ ์ •์˜จ ๋ฌผ๋ฅ˜์„ผํ„ฐ์— ๋Œ€ํ•œ ์ˆ˜์š”๊ฐ€ ์ฆ๊ฐ€ํ•˜๋ฉด์„œ, ์—๋„ˆ์ง€ ์†Œ๋น„์œจ์ด ๋†’์€ ์‚ฐ์—…๋ถ„์•ผ์ธ ์ •์˜จ๋ฌผ๋ฅ˜์„ผํ„ฐ[1]์™€ ๊ฐ™์€ ์—๋„ˆ์ง€ ๋‹ค์†Œ๋น„ ์‚ฐ์—…์ด ์ฆ๊ฐ€ํ•˜๊ณ  ์žˆ๋‹ค. ์—๋„ˆ์ง€ ๋‹ค์†Œ๋น„ ์‚ฐ์—…์˜ ์ฆ๊ฐ€๋Š” ์—๋„ˆ์ง€ ํšจ์œจํ™” ๊ธฐ์ˆ ๊ฐœ๋ฐœ์„ ์š”๊ตฌํ•˜๋Š” ๋ชฉ์†Œ๋ฆฌ๊ฐ€ ๋‚˜์˜ค๊ณ  ์žˆ๊ณ  ๊ด€๋ จ๋œ ์—ฐ๊ตฌ๋„ ์ง„ํ–‰๋˜๊ณ  ์žˆ๋‹ค[2-6].

์ „๋ ฅ๊ณต๊ธ‰์›์„ ์‹ ์žฌ์ƒ ๋ฐœ์ „์„ค๋น„๋กœ ์ „ํ™˜ํ•˜๊ธฐ ์œ„ํ•œ RE100[7] ์บ ํŽ˜์ธ์„ ์œ„ํ•œ ๋…ธ๋ ฅ์œผ๋กœ์„œ ์ „๊ธฐ์—๋„ˆ์ง€ ์‚ฌ์šฉ๋Ÿ‰์ด ๋†’์€ ์ •์˜จ๋ฌผ๋ฅ˜์„ผํ„ฐ์˜ ์ „๋ ฅ์›์„ ์‹ ์žฌ์ƒ ๋ฐœ์ „์„ค๋น„ ์ค‘ ํ•˜๋‚˜์ธ ํƒœ์–‘๊ด‘ PV๋กœ ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ๋‹ค. ๋˜ํ•œ ๊ณ„ํ†ต ํ”ผํฌ ๋ถ€ํ•˜์œจ ๊ฐ์†Œ๋Œ€์ฑ…์œผ๋กœ ์‚ฌ์šฉ๋˜๋Š” ESS์™€ ๋น„์ƒ ์ „์› ๊ณต๊ธ‰์žฅ์น˜ UPS์˜ ์‚ฌ์šฉ ์—ญ์‹œ ๊ณ ๋ คํ•  ์ˆ˜ ์žˆ๋‹ค.

์ •์˜จ๋ฌผ๋ฅ˜์„ผํ„ฐ์—์„œ ์ฃผ์š”ํ•œ ๋ถ€ํ•˜๋กœ ์‚ฌ์šฉ๋˜๋Š” ๋ƒ‰๋ฐฉ ๊ณต์กฐ์žฅ์น˜์™€, ์ปจ๋ฒ ์ด์–ด ์‹œ์Šคํ…œ์˜ ๊ฒฝ์šฐ AC ๋ถ€ํ•˜์— ํ•ด๋‹น๋˜๋‚˜ LED, ์ „๊ธฐ ์ˆ˜์†ก ํŠธ๋Ÿญ์˜ ๋ฐฐํ„ฐ๋ฆฌ ์ถฉ์ „์‹œ์Šคํ…œ ๋ฐ ์„œ๋ฒ„์žฅ์น˜์™€ ๊ฐ™์€ DC๋ถ€ํ•˜๋„ ์ „์ฒด ๋ถ€ํ•˜ ์‹œ์Šคํ…œ ์ค‘ ๋น„์ค‘์ด ์ปค์ง€๋Š” ๊ฐ€์šด๋ฐ AC ๋ฐฐ์ „๋ฐฉ์‹์— ์ถ”๊ฐ€์ ์ธ LVDC ๋ฐฐ์ „๋ผ์ธ์„ ์ ์šฉํ•จ์œผ๋กœ์„œ ์ „๋ ฅ๋ณ€ํ™˜ ์žฅ์น˜์˜ ๊ฐ์†Œ์™€ ์ „๋ ฅ๋ณ€ํ™˜ ์†์‹ค์„ ์ค„์ผ ์ˆ˜ ์žˆ๋‹ค.

์ œ์•ˆํ•˜๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์€ ์ „๋ ฅ๋ณ€ํ™˜ ํšจ์œจ ์ฆ๋Œ€๋ฅผ ์œ„ํ•˜์—ฌ ๊ต๋ฅ˜์ „์› ๊ฒฐํ•ฉ ๊ธฐ๋ฐ˜์˜ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์„ ์ง๋ฅ˜์ „์› ๊ฒฐํ•ฉ ์‹œ์Šคํ…œ์œผ๋กœ ๊ตฌ์„ฑํ•˜์—ฌ ๊ต๋ฅ˜-์ง๋ฅ˜[8] ๋ณ€ํ™˜ ์‹œ ์š”๊ตฌ๋˜๋Š” ์ „๋ ฅ๋ณ€ํ™˜ ์†Œ์ž์ˆ˜๋ฅผ ๊ฐ์†Œํ•˜๋ฉฐ, ์ „๋ ฅ ๋ณ€ํ™˜ ์†์‹ค๊ฐ์†Œ ๋˜ํ•œ ๊ฐ€๋Šฅ์ผ€ ํ•˜๋Š” ์‹œ์Šคํ…œ์ด๋‹ค[9]. ๋ณธ ๋…ผ๋ฌธ์—์„œ๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์ œ์–ด๋ฅผ ์œ„ํ•˜์—ฌ ๊ณ„ํ†ต ์ „๋ ฅ ์‚ฌ์šฉ๋Ÿ‰ ๊ธฐ๋ฐ˜ ํ”ผํฌ-์‰์ด๋น™ ๊ณก์„ ๊ณผ ํƒœ์–‘๊ด‘ ๋ฐœ์ „ ๋ฐ์ดํ„ฐ๋ฅผ ์œตํ•ฉํ•œ ์•Œ๊ณ ๋ฆฌ์ฆ˜์„ ์ ์šฉํ•˜์˜€์œผ๋ฉฐ, ESS ๋ฐฐํ„ฐ๋ฆฌ์˜ SoC ์ƒํƒœ๊ธฐ๋ฐ˜ ์ œ์–ด ์‹œํ€€์Šค๋ฅผ ๊ฐ„๋‹จํ•œ ์ˆœ์„œ๋„๋ฅผ ํ†ตํ•ด ๊ธฐ์ˆ ํ•˜์˜€๋‹ค. ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ ์‹œ๋ฎฌ๋ ˆ์ด์…˜๊ณผ ์„ค๊ณ„ ๊ทธ๋ฆฌ๊ณ  ์‹คํ—˜๋‚ด์šฉ์„ ๊ธฐ์ˆ ํ•˜๋ฉฐ ์ œ์•ˆํ•˜๋Š” ์žฅ์น˜์˜ ์‹คํšจ์„ฑ์„ ๊ฒ€ํ† ํ•˜์˜€๋‹ค.

2. ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ

2์žฅ์—์„œ๋Š” ๋…ผ๋ฌธ์—์„œ ์ œ์•ˆํ•˜๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ๊ธฐ๋ณธ๋™์ž‘๊ณผ ๊ตฌ์„ฑ์„ ์„ค๋ช…ํ•œ๋‹ค. ๊ทธ๋ฆฌ๊ณ  ํ”ผํฌ-์‰์ด๋น™๊ณผ ESS๋ฅผ ์ ์šฉํ•œ ์ผ๊ฐ„ ๊ณ„ํ†ต ์ „๋ ฅ ์‚ฌ์šฉ๋Ÿ‰์„ ๊ณ ๋ คํ•œ ์ œ์–ด ์•Œ๊ณ ๋ฆฌ์ฆ˜์„ ์„ค๋ช…ํ•œ๋‹ค. ๋˜ํ•œ ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์ œ์ž‘์„ ์„ค๋ช…ํ•˜๊ณ  ์‹œ๋ฎฌ๋ ˆ์ด์…˜๊ณผ ์‹คํ—˜์„ ํ†ตํ•ด์„œ ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์œ ํšจ์„ฑ์„ ๊ฒ€์ฆํ•œ๋‹ค.

2.1 ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ๊ตฌ์„ฑ

Fig. 1์˜ ๊ฐœ๋…๋„๋Š” ๋…ผ๋ฌธ์—์„œ ์ œ์•ˆํ•˜๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์„ ๋‚˜ํƒ€๋‚ธ๋‹ค. ํ†ตํ•ฉํ˜• ๋‹ค์ค‘์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์€ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ, ESS ์ปจ๋ฒ„ํ„ฐ, PV ์ปจ๋ฒ„ํ„ฐ ๊ทธ๋ฆฌ๊ณ  LVDC ์ปจ๋ฒ„ํ„ฐ๋กœ ๊ตฌ์„ฑํ•œ๋‹ค. ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ ๋ณ€ํ™˜์žฅ์น˜๋ฅผ AC ์ปคํ”Œ๋ง ํ•  ๋•Œ์™€ ๋น„๊ตํ•˜์—ฌ ์ „๋ ฅ๋ณ€ํ™˜ ํšจ์œจ ์ฆ๊ฐ€, DC ์ปคํ”Œ๋ง ํ•  ๊ฒฝ์šฐ ์Šค์œ„์น˜ ์†Œ์ž์˜ ๊ฐœ์ˆ˜์˜ ๊ฐ์†Œ์˜ ์ด์ ์„ ๊ฐ–๋Š”๋‹ค. ๋˜ํ•œ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๋Š” ์˜คํ”„๋ผ์ธ UPS์˜ ๊ธฐ๋Šฅ์„ ํ•  ์ˆ˜ ์žˆ๋‹ค. PMS(Power Management System)๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์ด๊ด„์ œ์–ด๋ฅผ ๋‹ด๋‹นํ•œ๋‹ค. ESS ์ปจ๋ฒ„ํ„ฐ์™€ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๋Š” ์–‘๋ฐฉํ–ฅ ์ถœ๋ ฅ, PV ์ปจ๋ฒ„ํ„ฐ์™€ LVDC ์ปจ๋ฒ„ํ„ฐ๋Š” ๋‹จ๋ฐฉํ–ฅ ์ถœ๋ ฅ์„ ํ•œ๋‹ค. DC ์ปคํ”Œ๋ง๋ถ€๋Š” DC-Link ์ปคํŒจ์‹œํ„ฐ์˜ ์ „์••์ด ์ผ์ •ํ•˜๊ฒŒ ์œ ์ง€๋˜๋„๋ก ESS ์ปจ๋ฒ„ํ„ฐ์™€ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์—์„œ ์ฃผ์š” ์ „์••์ œ์–ด๋ฅผ ์ˆ˜ํ–‰ํ•œ๋‹ค. ๋…ผ๋ฌธ์—์„œ ์ œ์•ˆํ•˜๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์€ ํ•˜๋‚˜์˜ DC ์ปคํ”Œ๋ง์„ ๋‹ค๋ฅธ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ๊ณผ ๊ณต์œ ํ•˜๋Š” ์‹œ์Šคํ…œ์ด๋‹ค. ๊ธฐ์กด ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์€ ์–‘๋ฐฉํ–ฅ PCS๊ฐ€ ๋ณ„๋„๋กœ ๋‹จ๋… ์žฅ๋น„๋กœ ์„ค์น˜ํ•˜๊ณ , ํƒœ์–‘๊ด‘ ์ธ๋ฒ„ํ„ฐ๋„ ๋ณ„๋„๋กœ ์„ค์น˜ํ•˜์˜€๋‹ค. PCS์™€ ํƒœ์–‘๊ด‘ ์ธ๋ฒ„ํ„ฐ๋Š” ๊ฐ๊ฐ ๊ณ„ํ†ต์œผ๋กœ ์—๋„ˆ์ง€๋ฅผ ๋ฐฉ์ „ํ•˜๋Š” ๋™์ผํ•œ ์—ญํ• ์„ ํ•˜๋Š” ์ „๋ ฅ๋ณ€ํ™˜์žฅ์น˜ ์ค‘์ฒฉ๋œ๋‹ค. ๊ทธ๋ฆฌ๊ณ  ์ค‘์ฒฉ๋˜๋Š” ์ „๋ ฅ๋ณ€ํ™˜ ์žฅ์น˜๋Š” ์ „๋ ฅ์†์‹ค์„ ์•ผ๊ธฐํ•˜๊ฒŒ ๋œ๋‹ค. ๋…ผ๋ฌธ์—์„œ ์ œ์•ˆํ•˜๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์€ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์—์„œ DC-Link ์ „์••์„ ํ•ญ์ƒ ์ผ์ •ํ•˜๊ฒŒ ์œ ์ง€ํ•˜๊ธฐ ํ•œ๋‹ค. ๊ทธ๋ฆฌ๊ณ  ๋‚ฎ ์‹œ๊ฐ„๋™์•ˆ ํƒœ์–‘๊ด‘ ๋ฐœ์ „์ด ๋˜๋ฉด PV ์ปจ๋ฒ„ํ„ฐ์˜ ์ถœ๋ ฅ์ด ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์— DC ์ปคํ”Œ๋ง๋˜์–ด ์žˆ๊ธฐ ๋•Œ๋ฌธ์— DC-Link์˜ ์ „์••์ด ๋†’์•„์ง„๋‹ค. ๊ทธ๋ฆฌ๊ณ  ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๋Š” ๋ถ€ํ•˜ ๋˜๋Š” ๊ณ„ํ†ต์œผ๋กœ PV ์ปจ๋ฒ„ํ„ฐ์—์„œ ๋ฐœ์ „๋œ ์ „๋ ฅ์„ ๋ฐฉ์ „ํ•ด์„œ DC-Link ์ „์••์„ ์ผ์ •ํ•˜๊ฒŒ ์œ ์ง€ํ•œ๋‹ค. DC ์ปคํ”Œ๋ง๋œ ์‹œ์Šคํ…œ์„ ์‚ฌ์šฉํ•˜์—ฌ ์ „๋ ฅ์Šค์œ„์น˜ ๊ฐœ์ˆ˜๋ฅผ์ค„๊ธฐ๊ณ  ์ „๋ ฅ ๋ณ€ํ™˜ํšจ์œจ์„ ๋†’์ด๋Š” ๋ฐฉ์‹์„ ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์ด๋ผ๊ณ  ํ•œ๋‹ค.

Fig. 1. Proposed integrated multi-power conversion system

../../Resources/kiiee/JIEIE.2025.39.1.22/fig1.png

Fig. 2๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ํšŒ๋กœ ๊ตฌ์„ฑ์ด๋‹ค. ๊ณ„ํ†ต ์ „์›๊ณผ ์ธ๋ฒ„ํ„ฐ์˜ ์ถœ๋ ฅ ์ „์›์„ ์ „ํ™˜ํ•  ์ˆ˜ ์žˆ๋Š” ์Šคํƒœํ‹ฑ ์Šค์œ„์น˜๊ฐ€ ์žˆ๊ณ , ๋ฐฐํ„ฐ๋ฆฌ ๋˜๋Š” ํƒœ์–‘๊ด‘ ๋ฐœ์ „ ์—๋„ˆ์ง€๋ฅผ ๊ณ„ํ†ต์œผ๋กœ ๋ฐฉ์ „ํ•˜๊ฑฐ๋‚˜ ๊ณ„ํ†ต ๋˜๋Š” ํƒœ์–‘๊ด‘ ๋ฐœ์ „ ์—๋„ˆ์ง€๋ฅผ ๋ฐฐํ„ฐ๋ฆฌ๋กœ ์ถฉ์ „ํ•˜๋Š” ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๊ฐ€ ์žˆ๋‹ค. ๊ทธ๋ฆฌ๊ณ  ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์˜ DC-Link์™€ DC ์ปคํ”Œ๋ง์ด ๋˜์–ด์žˆ๋Š” ์ถœ๋ ฅ ๋‹จ๋ฐฉํ–ฅ LVDC ์ปจ๋ฒ„ํ„ฐ ๊ทธ๋ฆฌ๊ณ  PV ๋ถ€์ŠคํŠธ ์ปจ๋ฒ„ํ„ฐ์˜ ์ถœ๋ ฅ์ด DC ์ปคํ”Œ๋ง ๋˜์–ด์žˆ๋Š” PV์ปจ๋ฒ„ํ„ฐ๋กœ ๊ตฌ์„ฑ๋˜์–ด์žˆ๋‹ค.

Fig. 2. Circuit composition of integrated multi-power conversion system

../../Resources/kiiee/JIEIE.2025.39.1.22/fig2.png

2.2 ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์•Œ๊ณ ๋ฆฌ์ฆ˜

Fig. 3์€ ESS๋ฅผ ์ ์šฉํ•œ ์ผ๊ฐ„ ๊ณ„ํ†ต ์ „๋ ฅ์‚ฌ์šฉ๋Ÿ‰์˜ ํƒœ์–‘๊ด‘ ๋ฐœ์ „ ์ „๋ ฅ๋Ÿ‰ ๊ณก์„ ๊ณผ ํ”ผํฌ-์‰์ด๋น™ ๊ณก์„ ์„ ๋‚˜ํƒ€๋‚ธ๋‹ค. ๊ณ„ํ†ต์†Œ๋น„์ „๋ ฅ์˜ ํ”ผํฌ๊ตฌ๊ฐ„์—์„œ ํƒœ์–‘๊ด‘ ๋ฐœ์ „์ „๋ ฅ๊ณผ ESS๋ฐฉ์ „์œผ๋กœ ์ „๋ ฅ ํ”ผํฌ๋ฅผ ํ•ด์†Œํ•˜๊ณ  ์˜คํ”„-ํ”ผํฌ ๊ตฌ๊ฐ„์—์„œ๋Š” ๊ณ„ํ†ต ์ „์›์œผ๋กœ ESS๋ฅผ ์ถฉ์ „ํ•˜์—ฌ ํ”ผํฌ๋ถ€ํ•˜๋ฅผ ์กฐ์ • ํ•  ์ˆ˜ ์žˆ์–ด์„œ ์ „๊ธฐ ์š”๊ธˆ์„ ์ค„์ผ ์ˆ˜ ์žˆ๋‹ค.

Fig. 3์€ ์ง๊ด€์ ์ธ ์ดํ•ด๋ฅผ ๋•๊ธฐ ์œ„ํ•œ ์˜ˆ์‹œ ์ž๋ฃŒ์ด๋ฉฐ ์‹ค์ œ ๋ฐ์ดํ„ฐ๋Š” ๋ณ€๋™๋ฅ ์ด ๋งค์šฐ ๋†’์•„์„œ ํ†ตํ•ฉํ˜• ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์ œ์–ด๋Š” Fig. 4์˜ ์•Œ๊ณ ๋ฆฌ์ฆ˜ ์‹œํ€€์Šค๋ฅผ ๊ธฐ๋ฐ˜์œผ๋กœ ์ˆ˜ํ–‰ํ•œ๋‹ค. State 0์€ ๊ณ„ํ†ต์˜ ์ •์ „ ์ƒํƒœ์ด๋ฉฐ ์ด๋•Œ ์ธ๋ฒ„ํ„ฐ๋ชจ๋“œ๋กœ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๋Š” ๋™์ž‘ํ•˜๊ณ , ๋ฐฐํ„ฐ๋ฆฌ SoC(State of Charge)๊ฐ€ 10% ๋ฏธ๋งŒ์ด ๋  ๋•Œ ๊นŒ์ง€ ๋ฐฉ์ „๋ชจ๋“œ๋กœ ESS ์ปจ๋ฒ„ํ„ฐ๊ฐ€ ๋™์ž‘ํ•œ๋‹ค.

State 1์—์„œ ๊ณ„ํ†ต์€ ์˜คํ”„-ํ”ผํฌ ๊ตฌ๊ฐ„์ด๊ณ  PV ๋ฐœ์ „๋Ÿ‰์ด ์—†๋Š” ๊ตฌ๊ฐ„์ด๋ฉฐ, ๊ณ„ํ†ต์ „์›์œผ๋กœ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์ถฉ์ „ํ•˜๊ณ  ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๋Š” ์ •๋ฅ˜๊ธฐ๋ชจ๋“œ๋กœ ๋™์ž‘ํ•œ๋‹ค. State 2๋Š” ๊ณ„ํ†ต์˜ ๋ถ€๋ถ„-ํ”ผํฌ๊ตฌ๊ฐ„์ด๋‹ค. PV ๋ฐœ์ „๋Ÿ‰์ด ๋†’์€ ๊ตฌ๊ฐ„์ด๊ณ , ๋ฐฐํ„ฐ๋ฆฌ SoC 90% ๊นŒ์ง€ PV์—๋„ˆ์ง€๋กœ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์ถฉ์ „ํ•˜๊ณ  90%์ด์ƒ๋ถ€ํ„ฐ๋Š” PV ๋ฐœ์ „์ „๋ ฅ์ด ๊ณ„ํ†ต์œผ๋กœ ๊ณต๊ธ‰๋œ๋‹ค. State 3์€ ๊ณ„ํ†ต์˜ ํ”ผํฌ๊ตฌ๊ฐ„์ด๋‹ค. PV ๋ฐœ์ „๋Ÿ‰์ด ๋†’์€ ๊ตฌ๊ฐ„์ด๊ณ , ๋ฐฐํ„ฐ๋ฆฌ ์ถฉ์ „์ƒํƒœ์— ๋”ฐ๋ผ PV๋ฐœ์ „ ์—๋„ˆ์ง€๊ฐ€ ๊ณ„ํ†ต์œผ๋กœ ๊ณต๊ธ‰๋œ๋‹ค. ๋˜ํ•œ SoC 60% ๊นŒ์ง€๋Š” ๋ฐฐํ„ฐ๋ฆฌ์˜ ์—๋„ˆ์ง€๋ฅผ ๊ณ„ํ†ต์œผ๋กœ ๊ณต๊ธ‰ํ•œ๋‹ค. PV ๋ฐœ์ „๋Ÿ‰์ด ๋ถ€์กฑํ•˜๊ณ  ๊ณ„ํ†ต์˜ ๋ถ€๋ถ„-ํ”ผํฌ ๊ตฌ๊ฐ„์ธ ๊ฒฝ์šฐ๋Š” State 1์— ํ•ด๋‹นํ•œ๋‹ค.

Fig. 3. Peak-shaving curve of daily grid power consumption using ESS and PV power generation curve

../../Resources/kiiee/JIEIE.2025.39.1.22/fig3.png

Fig. 4. Flowchart of the proposed integrated multi-power conversion system sequence algorithm

../../Resources/kiiee/JIEIE.2025.39.1.22/fig4.png

2.3 ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์‹œ๋ฎฌ๋ ˆ์ด์…˜

Fig. 5๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์„ ๊ฒ€์ฆํ•˜๊ธฐ์œ„ํ•ด ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ํ•˜์˜€์œผ๋ฉฐ ์‹œ๋ฎฌ๋ ˆ์ด์…˜ ํˆด์€ PSIM์„ ์‚ฌ์šฉํ•˜์˜€๋‹ค. ์‹œ๋ฎฌ๋ ˆ์ด์…˜์— ์‚ฌ์šฉํ•œ ์ œ์–ด๊ธฐ๋Š” d์ถ•, q์ถ•, 0์ƒ ์ „์•• PI ์ œ์–ด๊ธฐ๊ฐ€ ์™ธ๋ถ€ ๋ฃจํ”„์˜ ๊ต๋ฅ˜ ์ „์••์„ ์ œ์–ดํ•˜๊ณ  d์ถ•, q์ถ•, 0์ƒ ์ „๋ฅ˜ P ์ œ์–ด๊ฐ€ ๋‚ด๋ถ€ ๋ฃจํ”„์˜ ๊ต๋ฅ˜ ์ „๋ฅ˜๋ฅผ ์ œ์–ดํ•œ๋‹ค. 3์ƒ ๊ต๋ฅ˜ ์ „์••๊ฐ’์€ ABC ์ขŒํ‘œ์ถ•์—์„œ DQ0 ์ขŒํ‘œ์ถ•์œผ๋กœ ๋ณ€ํ™˜ํ•˜์—ฌ DQ0์ถ• ์ƒ์—์„œ ์ œ์–ด๊ฐ€ ์ˆ˜ํ–‰ํ•œ๋‹ค. ๊ทธ๋ฆฌ๊ณ  d์ถ•, q์ถ•, 0์ถ• ์ „์•• PI ์ œ์–ด๊ธฐ๋Š” ์ง€๋ น๊ฐ’์„ ์ธก์ •๊ฐ’๊ณผ ๋น„๊ตํ•˜์—ฌ ์ถœ๋ ฅ๊ฐ’์„ ๋งŒ๋“ ๋‹ค.

Fig. 5. (a) Bi-directional inverter power part simulation schematic of integrated multi-power converter system and (b) Bi-directional inverter gate part simulation schematic of integrated multi-power converter system and (c) Bi-directional inverter control part simulation schematic of integrated multi-power converter system

../../Resources/kiiee/JIEIE.2025.39.1.22/fig5.png

๊ทธ๋ฆฌ๊ณ  d์ถ• ์ „์•• ์ œ์–ด๊ธฐ์˜ ์ง€๋ น๊ฐ’์€ 0์œผ๋กœ ํ•˜๊ณ  q์ถ• ์ „์•• ์ œ์–ด๊ธฐ์˜ ์ง€๋ น๊ฐ’์„ ์ถœ๋ ฅํ•˜๊ณ ์ž ํ•˜๋Š” ๊ต๋ฅ˜ ์ „์••๊ฐ’์— ํ•ด๋‹นํ•˜๋Š” ๊ฐ’์œผ๋กœ ์ ์šฉํ•˜๊ณ , ์ถœ๋ ฅ ๊ต๋ฅ˜ ์ „์••์˜ ์˜ต์…‹์„ฑ๋ถ„์„ 0์œผ๋กœ ํ•˜๊ธฐ ์œ„ํ•˜์—ฌ 0์ƒ ์ „์•• ์ œ์–ด๊ธฐ์˜ ์ง€๋ น๊ฐ’์€ 0์œผ๋กœ ์ ์šฉํ•œ๋‹ค. d์ถ•, q์ถ•, 0์ƒ ์ „์•• PI ์ œ์–ด๊ธฐ์˜ ์ถœ๋ ฅ๊ฐ’์€ d์ถ•, q์ถ•, 0์ƒ ์ „๋ฅ˜ P ์ œ์–ด๊ธฐ์˜ ์ง€๋ น๊ฐ’์ด ๋˜๋ฉฐ d์ถ•, q์ถ•, 0์ƒ ์ „๋ฅ˜ P ์ œ์–ด๊ธฐ์˜ ์ถœ๋ ฅ๊ฐ’์„ DQ0 ์ขŒํ‘œ์ถ•์—์„œ ABC ์ขŒํ‘œ์ถ•์œผ๋กœ ๋ณ€ํ™˜ํ•˜์—ฌ PWM ์‹ ํ˜ธ๋ฅผ ์ƒ์„ฑํ•œ๋‹ค.

Table 1์€ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์— ์‚ฌ์šฉํ•œ ํŒŒ๋ผ๋ฏธํ„ฐ์ด๋‹ค.

Table 1. Simulation parameter of integrated multi-power converter system

Parameter

Value

Grid Voltage L-L

380Vrms

Grid Frequency, f

60Hz

Rated power

250kW

DC Link Voltage, Vdc

760VDC

Filter Inductance

360ฮผH

Filter Capacitor

450ฮผF

Switching Frequency

5.4kHz

Fig. 6์€ ๊ณ„ํ†ต ์—๋„ˆ์ง€๋กœ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์ถฉ์ „ํ•˜๋Š” ์ˆœ๊ฐ„์˜ ๊ณผ๋„์ƒํƒœ๋ฅผ ํ™•์ธํ•˜๊ธฐ ์œ„ํ•˜์—ฌ ๋ณธ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ์ˆ˜ํ–‰ํ•˜์˜€๋‹ค. ๊ณ„ํ†ต์˜ ์—๋„ˆ์ง€๋ฅผ ๋ฐฐํ„ฐ๋ฆฌ๋กœ ์ถฉ์ „ํ•˜๋Š” ์ˆœ๊ฐ„์— ๋ฐฐํ„ฐ๋ฆฌ ์ „๋ฅ˜๋Š” ํ”Œ๋Ÿฌ์Šค ์ชฝ์œผ๋กœ ํ๋ฅด๊ณ  ๋ฌดํšจ์ „๋ ฅ ์„ฑ๋ถ„ d์ถ• ์ „๋ฅ˜๋Š” ์ผ์ •ํ•˜๊ฒŒ ์ œ์–ด๋˜๊ณ  ์œ ํšจ์ „๋ ฅ ์„ฑ๋ถ„ q์ถ• ์ „๋ฅ˜๊ฐ€ ์ œ์–ด๋˜๋Š” ๊ฒƒ์„ ํ™•์ธํ•  ์ˆ˜ ์žˆ๋‹ค.

Fig. 6. Simulate charging the battery from the grid energy

../../Resources/kiiee/JIEIE.2025.39.1.22/fig6.png

Fig. 7์€ ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ๋ฐฐํ„ฐ๋ฆฌ ์—๋„ˆ์ง€๋ฅผ ๊ณ„ํ†ต์œผ๋กœ ๋ฐฉ์ „ ์ˆœ๊ฐ„์˜ ๊ณผ๋„์ƒํƒœ๋ฅผ ํ™•์ธํ•˜๊ธฐ ์œ„ํ•˜์—ฌ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์„ ํ•˜์˜€๋‹ค. ๋ฐฐํ„ฐ๋ฆฌ์ „๋ฅ˜๋Š” ์ถฉ์ „์˜ ๋ฐ˜๋Œ€๋ฐฉํ–ฅ์œผ๋กœ ํ๋ฅด๋Š” ๊ฒƒ์„ ํ™•์ธํ•  ์ˆ˜ ์žˆ๋‹ค. ์ด ๋•Œ๋„ ๋งˆ์ฐฌ๊ฐ€์ง€๋กœ ๋ฌดํšจ์ „๋ ฅ ์„ฑ๋ถ„ d์ถ•, ์œ ํšจ์ „๋ ฅ ์„ฑ๋ถ„ q์ถ• ์ „๋ฅ˜์˜ ์ œ์–ด๊ฐ€ ์ž˜ ๋˜๋Š” ๊ฒƒ์„ ํ™•์ธํ•  ์ˆ˜ ์žˆ๋‹ค.

Fig. 7. Simulate discharging the battery energy to the grid

../../Resources/kiiee/JIEIE.2025.39.1.22/fig7.png

Fig. 8์€ ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๊ฐ€ ๋ฐฐํ„ฐ๋ฆฌ์—์„œ ๊ณ„ํ†ต์œผ๋กœ ๋ฐฉ์ „ํ•˜๋‹ค๊ฐ€ ๊ณ„ํ†ต์—์„œ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์ถฉ์ „ํ•  ๋•Œ์˜ ๊ณผ๋„ํŠน์„ฑ์„ ํ™•์ธํ•˜๊ธฐ ์œ„ํ•œ ์‹œ๋ฎฌ๋ ˆ์ด์…˜์ด๋‹ค. ๋ฐฐํ„ฐ๋ฆฌ์ „๋ฅ˜๊ฐ€ ๋ฐฉ์ „์—์„œ ์ถฉ์ „์œผ๋กœ ์ „ํ™˜๋˜๋Š” ์ˆœ๊ฐ„์—๋„ ๋ฌดํšจ์ „๋ ฅ ์„ฑ๋ถ„์ธ d์ถ•, ์œ ํšจ์ „๋ ฅ ์„ฑ๋ถ„์ธ q์ถ•์˜ ์ „๋ฅ˜์™€ ์ „์••์˜ ์ œ์–ด๊ฐ€ ์•ˆ์ •์ •์œผ๋กœ ๋˜๋Š” ๊ฒƒ์„ ํ™•์ธํ•  ์ˆ˜ ์žˆ๋‹ค.

Fig. 8. Simulate charging the battery from the gid energy during battery energy discharge to the grid

../../Resources/kiiee/JIEIE.2025.39.1.22/fig8.png

2.4 ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์‹คํ—˜ ๋ฐ ๊ฒฐ๊ณผ

Fig. 9๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์‹คํ—˜์— ์‚ฌ์šฉํ•œ 250kW ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์˜ ์„ค๊ณ„๋„์ด๋‹ค. ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๋Š” 2๊ฐœ์˜ ๋ž™์„ ์—ด๋ฐ˜ํ•˜์—ฌ ๊ตฌ์„ฑ๋œ๋‹ค. ์ขŒ์ธก๋ž™์€ I/O ๋ž™์œผ๋กœ ํ•œ์ „์˜ ๊ณ„ํ†ต ์ „๋ ฅ์„ ๊ณผ ๋ฐฐํ„ฐ๋ฆฌ ์—ฐ๊ฒฐ ์ „๋ ฅ์„ ์„ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์— ์—ฐ๊ฒฐํ•˜๊ณ  ์Šค์œ„์น˜๋ฅผ ์กฐ์ž‘ํ•˜์—ฌ ๊ณ„ํ†ต ๋˜๋Š” ๋ฐฐํ„ฐ๋ฆฌ์— ๊ฐœํํ•˜๋Š” ์šฉ๋„๋กœ ์„ค๊ณ„ํ•˜์˜€๋‹ค. ๊ทธ๋ฆฌ๊ณ  ์šฐ์ธก ๋ž™์€ ํŒŒ์›Œ ๋ชจ๋“ˆ๋ž™์œผ๋กœ IGBT ํšŒ๋กœ๋ฅผ ๋ชจ๋“ˆํ˜•ํƒœ๋กœ ์ œ์ž‘ํ•˜์—ฌ ์œ ์ง€๋ณด์ˆ˜๊ฐ€ ์šฉ์ดํ•˜๊ณ  ์„ค์น˜๊ณต๊ฐ„ ์ตœ์†Œํ™”ํ•  ์ˆ˜ ์žˆ๋„๋ก ์ œ์ž‘ํ•˜์˜€๋‹ค.

Fig. 9. Bi-directional inverter appearance of integrated multi-power power conversion systems

../../Resources/kiiee/JIEIE.2025.39.1.22/fig9.png

Fig. 10์€ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์˜ ๊ตฌ์„ฑ์ด๋‹ค. IGBT ๋ชจ๋“ˆ์ด ์žˆ๋Š” ์ „๋ ฅํšŒ๋กœ๋Š” ์œ ์ง€๋ณด์ˆ˜์— ์šฉ์ดํ•˜๊ฒŒ ํƒˆ๊ฑฐ ๋ฐ ์žฅ์ฐฉ์— ํŽธ๋ฆฌํ•œ ๋ชจ๋“ˆ ํ˜•ํƒœ ๊ตฌ์„ฑ ๋˜์–ด์žˆ๋‹ค. R์ƒ, S์ƒ, T์ƒ 3๊ฐœ์˜ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ ์Šค์œ„์น˜ ๋ชจ๋“ˆ๊ณผ ๋ฐฐํ„ฐ๋ฆฌ์˜ ์ถฉ์ „๊ณผ ๋ฐฉ์ „์‹œ์˜ ์ผ์ •ํ•œ DC-Link ์ „์••์œผ๋กœ ์œ ์ง€ํ•˜๊ธฐ ์œ„ํ•œ ESS ์ปจ๋ฒ„ํ„ฐ ๊ทธ๋ฆฌ๊ณ  DC-Link ์ „์••์˜ ๋ถˆํ‰ํ˜•์„ ๋ฐฉ์ง€ํ•˜๊ธฐ ์œ„ํ•œ ๋ฐธ๋Ÿฐ์„œ๋กœ ์ด๋ฃจ์–ด์ ธ ์žˆ๋Š” DC-DC ์Šค์œ„์น˜ ๋ชจ๋“ˆ 1๊ฐœ๋กœ ๊ตฌ์„ฑ ํ•˜์˜€๋‹ค.

Fig. 10. Bi-directional inverter composition of integrated multi-power conversion systems

../../Resources/kiiee/JIEIE.2025.39.1.22/fig10.png

Table 2๋Š” ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์˜ ์ „๊ธฐ์  ํŠน์„ฑํ‘œ์ด๋‹ค.

Table 2. Electrical characteristics of bi-directional inverter

Rated Input Voltage

380Vrms(L-L), 3L4W

Input Voltage Range

ยฑ10%

Rated Frequency, f

60Hz

Rated power

250kW

Rated Output Voltage

380Vrms(L-L), 3L4W

Battery Voltage Range

550 ใ€œ 850VDC

THDi

Less than 5% (Rated charging and discharging)

Efficiency

More than 96%(Rated charging and discharging)

Fig. 11์€ PV ์ปจ๋ฒ„ํ„ฐ ์ œ์ž‘๋„์ด๋‹ค. PV ์…€ ์—ฐ๊ฒฐ๋‹จ์ž๋Š” ์•„๋ž˜์— ์ฒด๊ฒฐ๋œ๋‹ค. PV ์…€์„ ํšŒ๋กœ์— ์—ฐ๊ฒฐํ•˜๊ธฐ์œ„ํ•ด 4๊ฐœ์˜ ์ฑ„๋„์— ๊ฐ๊ฐ ์Šค์œ„์น˜๋ฅผ ์กฐ์ž‘ํ•˜์—ฌ ์—ฐ๊ฒฐ๋˜๋„๋ก ์„ค๊ณ„ํ•˜์˜€๋‹ค. ๊ทธ๋ฆฌ๊ณ  PV ์ปจ๋ฒ„ํ„ฐ์™€ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์˜ DC ์ปคํ”Œ๋ง ํ•˜๊ธฐ์œ„ํ•ด ์ถœ๋ ฅ ์Šค์œ„์น˜๋ฅผ ์กฐ์ž‘ํ•˜์—ฌ ์—ฐ๊ฒฐํ•  ์ˆ˜ ์žˆ๋‹ค.

Fig. 11. Description of each part of the PV converter

../../Resources/kiiee/JIEIE.2025.39.1.22/fig11.png

Table 3์€ PV ์ปจ๋ฒ„ํ„ฐ์˜ ์ „๊ธฐ์  ์‚ฌ์–‘ํ‘œ์ด๋‹ค.

Table 3. Electrical characteristics of PV converter

Input Voltage

250 ~ 750Vdc

Output Voltage

760Vdc

Rated power

100kW

Topology

4-MPPT Boost Converter

Efficiency

More than 98%(Rated)

Fig. 12๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์‹คํ—˜์„ ์œ„ํ•˜์—ฌ ์žฅ๋น„๋ฅผ ๊ตฌ์„ฑํ•œ ์‚ฌ์ง„์ด๋‹ค. PV์ปจ๋ฒ„ํ„ฐ์™€ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์˜ ์›๊ฒฉ์ œ์–ด๋ฅผ ์œ„ํ•˜์—ฌ PMS๋ฅผ ์„ค์น˜ํ•˜์˜€๋‹ค. PMS์—์„œ๋Š” ๊ฐ ์žฅ๋น„์˜ ์ œ์–ด๋ฅผ ์œ„ํ•ด์„œ ํ•„์š”ํ•œ ์ง€๋ น์„ ์ค„ ์ˆ˜ ์žˆ๋„๋ก ๊ตฌ์„ฑํ•˜์˜€๋‹ค. ๊ทธ๋ฆฌ๊ณ  ์šฐ์ธก์— PV ์ปจ๋ฒ„ํ„ฐ 100kW์™€ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ 250kW๋ฅผ ์„ค์น˜ํ•˜์—ฌ ํ…Œ์ŠคํŠธ๋ฅผ ์ง„ํ–‰ํ•˜์˜€๋‹ค.

Fig. 12. Experiment configuration of integrated multi-power conversion systems

../../Resources/kiiee/JIEIE.2025.39.1.22/fig12.png

Fig. 13์€ ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๊ฐ€ ๊ณ„ํ†ต์˜ ์—๋„ˆ์ง€๋กœ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์ถฉ์ „ํ•˜๋Š” ํŒŒํ˜•์ด๋‹ค. ์ธ๋ฒ„ํ„ฐ ์ „๋ฅ˜ (Iinv)์™€ ๊ณ„ํ†ต์ „์•• (Vgrid) ์˜ ์œ„์ƒ์ด ๊ฐ™์œผ๋ฏ€๋กœ ๋ฐฐํ„ฐ๋ฆฌ ์ „๋ฅ˜๋Š” ์ถฉ์ „์ƒํƒœ์ธ ๊ฒƒ์„ ํ™•์ธํ•  ์ˆ˜ ์žˆ๋‹ค. ์ธ๋ฒ„ํ„ฐ ์ „๋ฅ˜(Iinv) ๋Š” ๊ณ„ํ†ต์—์„œ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์ถฉ์ „ํ•˜๋Š” ์ „๋ฅ˜์ด๋‹ค. ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์˜ ์ •๊ฒฉ ์šฉ๋Ÿ‰์ด 250kW์—ฌ์„œ LCํ•„ํ„ฐ๋ฅผ ํฌํ•จํ•œ ์ „๋ ฅํšŒ๋กœ๊ฐ€ ์„ค๊ณ„๋˜์—ˆ์Šต๋‹ˆ๋‹ค. ์‹คํ—˜์‹œ์—๋Š” ์ •๊ฒฉ์˜ 30% ์ดํ•˜์˜ ๋ถ€ํ•˜๋กœ ํ…Œ์ŠคํŠธํ•˜์˜€๊ธฐ ๋•Œ๋ฌธ์— ์ธ๋ฒ„ํ„ฐ ์ „๋ฅ˜(Iinv) ๋ฐ ์ „๋ฅ˜ํŒŒํ˜•์˜ ์™œ๊ณก์ด ์ผ์–ด๋‚œ ๊ฒƒ์„ ํ™•์ธํ•  ์ˆ˜ ์žˆ๋‹ค. ์ „๋ฅ˜ ๋ฐฐํ„ฐ๋ฆฌ ์ „๋ฅ˜(Ibatt)๋Š” ์‹คํ—˜์—์„œ๋Š” ์ถฉ์ „์‹œ์— ๋งˆ์ด๋„ˆ์Šค๋กœ ์„ค์ •ํ•˜์˜€๋‹ค. ์ถฉ์ „ ์‹œ DC-link์ „์••(Vdc-link)๊ณผ ๋ฐฐํ„ฐ๋ฆฌ์ „์••(Vbatt)์ด ์ผ์ •ํ•˜๊ฒŒ ์œ ์ง€๋˜๋Š” ๊ฒƒ์„ ํ™•์ธํ•  ์ˆ˜ ์žˆ๋‹ค.

Fig. 13. Experiments with charging the battery in the system

../../Resources/kiiee/JIEIE.2025.39.1.22/fig13.png

Fig. 14๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๊ฐ€ ๊ณ„ํ†ต์˜ ์—๋„ˆ์ง€๋กœ ๋ฐฐํ„ฐ๋ฆฌ๋ฅผ ์ถฉ์ „ํ•˜๋‹ค๊ฐ€ ๊ณ„ํ†ต์œผ๋กœ ๋ฐฐํ„ฐ๋ฆฌ์˜ ์—๋„ˆ์ง€๋ฅผ ๋ฐฉ์ „ํ•  ๋•Œ์˜ ํŒŒํ˜•์ด๋‹ค. ์ถฉ์ „์‹œ์—๋Š” ์ธ๋ฒ„ํ„ฐ์ „๋ฅ˜(Iinv)์™€ ๊ณ„ํ†ต์ „์••(Vgrid)์˜ ์œ„์ƒ์ด ์ผ์น˜ํ•˜๋‹ค๊ฐ€ ๋ฐฉ์ „์‹œ์—๋Š” ์œ„์ƒ์ด ๋ฐ˜์ „๋˜๋Š” ๊ฒƒ์„ ํ™•์ธ ํ•  ์ˆ˜ ์žˆ๋‹ค. ์ด ๋•Œ ๋ฐฐํ„ฐ๋ฆฌ์ „๋ฅ˜(Ibatt)๋„ ์Œ์ˆ˜์—์„œ ์–‘์ˆ˜๋กœ ์ „ํ™˜๋˜๋Š” ๊ฒƒ์„ ํ™•์ธํ•  ์ˆ˜ ์žˆ๋‹ค.

Fig. 14. Experiments with charging the battery from the grid energy during battery energy discharge to the grid

../../Resources/kiiee/JIEIE.2025.39.1.22/fig14.png

Fig. 15๋Š” ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์™€ PV ์ปจ๋ฒ„ํ„ฐ ์—ฐ๊ฒฐํ•˜๋Š” ์‹คํ—˜์˜ ํŒŒํ˜•์ด๋‹ค. PV ์ปจ๋ฒ„ํ„ฐ์—์„œ ํƒœ์–‘๊ด‘ ์…€์„ ํ†ตํ•ด์„œ ๋ฐœ์ „๋˜๋Š” ํƒœ์–‘๊ด‘ ๋ฐœ์ „ ์ „๋ฅ˜(Ipv)๋Š” MPPT ์ œ์–ด๋กœ ์ผ์ •ํ•˜๊ฒŒ ์œ ์ง€๋œ๋‹ค. ๊ทธ๋ฆฌ๊ณ  ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๋Š” PV ์ปจ๋ฒ„ํ„ฐ์˜ ์ถœ๋ ฅ์ด DC-Link์— ์—ฐ๊ฒฐ๋˜์–ด ์žˆ๊ธฐ ๋•Œ๋ฌธ์— PV ์ปจ๋ฒ„ํ„ฐ์˜ ๋ฐœ์ „๋Ÿ‰ ๋งŒํผ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์˜ DC-Link ์ „์••์ด ์ƒ์Šนํ•˜๋ฉฐ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ๊ฐ€ DC-Link์˜ ์ „์•• ์ƒ์Šน์„ ๊ฒ€์ถœํ•˜์—ฌ ๊ณ„ํ†ต์œผ๋กœ ๋ฐฉ์ „ํ•œ๋‹ค.

Fig. 15. Experimental PV converter linkage

../../Resources/kiiee/JIEIE.2025.39.1.22/fig15.png

๋ณธ ๋…ผ๋ฌธ์˜ ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์€ ํ˜„์žฌ ๊ฐœ๋ฐœ ์ค‘์ด์–ด์„œ ์ •๊ฒฉ์œผ๋กœ ์‹คํ—˜ํ•˜์ง€ ๋ชปํ•˜์˜€๊ธฐ ๋•Œ๋ฌธ์— ํšจ์œจ ๊ฐœ์„ ํšจ๊ณผ๋Š” ํ™•์ธํ•  ์ˆ˜ ์—†์—ˆ๋‹ค. ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ํšจ์œจ ๊ฐœ์„ ํšจ๊ณผ๋ฅผ ๊ฒ€ํ† ํ•˜๊ธฐ ์œ„ํ•ด 3์ƒ ์ธ๋ฒ„ํ„ฐ์˜ ์ „๋ ฅ ์†์‹ค์„ ์ˆ˜์‹(1), (2), (3), (4)๋กœ ๊ฒ€ํ† ํ•˜์˜€๋‹ค[10]. PCOND๋Š” ๋„ํ†ต ์ „๋ ฅ, k(IC)๋Š” ์Šค์œ„์นญ ์†์‹ค ์ง€ํ‘œ, ESWITCH๋Š” ์Šค์œ„์นญ ์†์‹ค์ด๋‹ค.

(1)
$P_{COND}= c\bullet I_{C}+d\bullet I_{C}^{2}$
(2)
$P_{COND}(I_{C},\: T)=(c_{0}+c_{1}T)I_{C}+(d_{0}+d_{1}T)I_{C}^{2}$
(3)
$k(I_{C})=(a_{0}+a_{1}T)+(b_{0}+b_{1}T)I_{C}+(c_{0}+c_{1}T)I_{C}^{2}$
(4)
$E_{SWITCH}=k_{IGBT}(I_{C})\bullet I_{C}$

3. ๊ฒฐ ๋ก 

๋ณธ ๋…ผ๋ฌธ์—์„œ๋Š” ์—๋„ˆ์ง€ ๋‹ค์†Œ๋น„ ์‚ฐ์—…๋ถ„์•ผ์— ์ ์šฉํ•  ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์„ ๊ฐœ๋ฐœํ•˜์˜€๋‹ค. ์ด ์‹œ์Šคํ…œ์€ PV ์ปจ๋ฒ„ํ„ฐ, ESS, UPS, LVDC ์ปจ๋ฒ„ํ„ฐ๊ฐ€ ํ•˜๋‚˜์˜ DC๋งํฌ๋ฅผ ๊ฒฐํ•ฉํ•˜์—ฌ ๊ต๋ฅ˜-์ง๋ฅ˜ ๋ณ€ํ™˜ ์‹œ ์š”๊ตฌ๋˜๋Š” ์ „๋ ฅ๋ณ€ํ™˜ ์†์‹ค์„ ๊ฐ์†Œ์‹œํ‚จ๋‹ค. ๋ณธ ๋…ผ๋ฌธ์—์„œ๋Š” ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์˜ ์ œ์–ด๋ฅผ ์œ„ํ•˜์—ฌ ๊ณ„ํ†ต ์ „๋ ฅ ์‚ฌ์šฉ๋Ÿ‰ ๊ธฐ๋ฐ˜ ํ”ผํฌ-์‰์ด๋น™ ๊ณก์„ ๊ณผ ํƒœ์–‘๊ด‘ ๋ฐœ์ „ ๋ฐ์ดํ„ฐ๋ฅผ ์œตํ•ฉํ•œ ์•Œ๊ณ ๋ฆฌ์ฆ˜์„ ์ ์šฉํ•˜์˜€์œผ๋ฉฐ, ESS ๋ฐฐํ„ฐ๋ฆฌ์˜ SoC ์ƒํƒœ๊ธฐ๋ฐ˜ ์ œ์–ด ์‹œํ€€์Šค๋ฅผ ๊ฐ„๋‹จํ•œ ์ˆœ์„œ๋„๋ฅผ ํ†ตํ•ด ๊ธฐ์ˆ ํ•˜์˜€๋‹ค. ์‹œ๋ฎฌ๋ ˆ์ด์…˜์—์„œ๋Š” ๋ฐฐํ„ฐ๋ฆฌ์™€ ๊ณ„ํ†ต๊ฐ„ ์ „๋ ฅ๋ณ€ํ™˜ ํ๋ฆ„์„ ๋ชจ๋ธ๋งํ•˜์˜€์œผ๋ฉฐ ์ œ์–ด์„ฑ๋Šฅ์„ ๊ฒ€ํ† ํ•˜์˜€๋‹ค. ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์€ 250kW ์ถœ๋ ฅ์ด ๊ฐ€๋Šฅํ•œ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์™€ ์ถฉ์ „์žฅ์น˜๋“ค๋กœ ๊ตฌ์„ฑํ•˜์˜€๊ณ  ํŒŒ์›Œ ๋ชจ๋“ˆํ˜•ํƒœ๋กœ ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์žฅ์น˜๋“ค์˜ ํƒˆ๊ฑฐ ๋ฐ ์„ค์น˜๊ฐ€ ์šฉ์ดํ•œ ํ˜•ํƒœ๋กœ ์„ค๊ณ„ํ•˜์—ฌ ๋ณต์žกํ•œ ์‹œ์Šคํ…œ์˜ ์œ ์ง€๋ณด์ˆ˜ ํŽธ์˜์„ฑ๊ณผ ์„ค์น˜์‹œ ๋ฐœ์ƒํ•˜๋Š” ์ธ์  ๊ฒฐํ•จ ๋ฐœ์ƒ์œจ์„ ๊ฐ์†Œ์‹œ์ผฐ๋‹ค. ์‹คํ—˜์—์„œ๋Š” PMS๋กœ ํ†ตํ•ฉํ˜• ๋‹ค์ค‘ ์ „๋ ฅ๋ณ€ํ™˜ ์‹œ์Šคํ…œ์„ ์ด๊ด„ ์ œ์–ดํ•˜์—ฌ ์–‘๋ฐฉํ–ฅ ์ธ๋ฒ„ํ„ฐ์™€ ๋ฐฐํ„ฐ๋ฆฌ ์ปจ๋ฒ„ํ„ฐ๋ฅผ ์ƒ์‹œ ์ œ์–ดํ•  ๋•Œ ์•ˆ์ •์„ฑ์„ ๊ฒ€ํ† ํ•˜์˜€๋‹ค.

Acknowledgement

์ด ์—ฐ๊ตฌ๋Š” ์‚ฐ์—…ํ†ต์ƒ์ž์›๋ถ€(MOTIE)์™€ ํ•œ๊ตญ์—๋„ˆ์ง€๊ธฐ์ˆ ํ‰๊ฐ€์›(KETEP)์˜ ์ง€์›(No. 2021202080090)๊ณผ ํ•œ๊ตญ์—๋„ˆ์ง€๊ธฐ์ˆ ํ‰๊ฐ€์›(KETEP)์˜ ์ง€์›(No. 2022202080050)์„ ๋ฐ›์•„ ์ˆ˜ํ–‰ํ•œ ์—ฐ๊ตฌ ๊ณผ์ œ์ž„.

References

1 
H. I. Sin and J. S. Kim, โ€œDeveloping a package design for cold chain logistics services in a warming climate,โ€ KICPD, no. 72, pp. 71-80, 2023.URL
2 
K. H. Lee, โ€œLow voltage DC distribution technology for the green building,โ€ KIPE Magazine, vol. 15, no. 5, pp. 32-39, 2010.URL
3 
S. B. Lim, โ€œIntroduction of the high capacity hybrid UPS with ESS function,โ€ Proc. of Autumn Annual Conference, p. 22, 2017.URL
4 
S. P. Kim, J. G. Hwang, and S. J. Park, โ€œThe PCS system having the BESS function,โ€ Proc. of 2013 Power Electronics Annual Conference, pp. 34-35, 2013.URL
5 
S. J. Lee, et al., โ€œIntegrated operating technique for LVDC to connecting DC grid,โ€ Proc. of 2014 Power Electronics Annual Conference, pp. 558-559, 2014.URL
6 
Y. S. Oh, et al., โ€œEvaluation of reliability worth considering sustained interruptions and voltage sags,โ€ Journal of the KIIEE, vol. 22 no. 5, pp. 13-20, 2008.DOI
7 
H. Y. Sin and J. B. Park, โ€œAnalysis of global RE100 operation status and suggestions for expanding RE100 in South Korea,โ€ The Transactions of the Korean Institute of Electrical Ensineers, vol. 70, no. 11, pp. 1645-1654, 2021.DOI
8 
S. I. Paeng, J. U. Lim, and G. H. Choe, โ€œDevelopment of 3.3kW PV ESS system with DC power supply function,โ€ The Korean Institute of Illuminating and Electrical Installation Engineers, vol. 31, no. 11, pp. 119-130, 2017.DOI
9 
H. B. Cho, W. I. Lee, J. S. Kim, and S. B. Lim, โ€œDevelopment of an integrated multi-power conversion system to improve energy efficiency in Temperature -Controlled Logistics Center,โ€ Proc. of 2024 Power Electronics Annual Conference, pp. 748-749, 2024.URL
10 
C. Y. Oh, J. H. Han, S. M. Shin, and B. K. Lee, โ€œComparison of losses calculation method for power semiconductor switching device,โ€ Proc. of 2010 Power Electronics Annual Conference, pp. 361-362, 2024.URL

Biography

Won-Il Lee
../../Resources/kiiee/JIEIE.2025.39.1.22/au1.png

He received M.S. degree in power electronics from Kongju University in 2013. Since 2017, he has been working on Eon Co., Ltd as a researcher. His research interests are power converters, inverters, UPS and ESS.

Ji-Su Kim
../../Resources/kiiee/JIEIE.2025.39.1.22/au2.png

He received M.S. degree in power electronics from Konkuk University in 2012. Since 2007, he has been working on Eon Co., Ltd as a researcher. He is currently pursuing the Ph.D. degree at the Department of Energy System Engineering, Chung-Ang University, Seoul. His research interests are power converters, inverters, UPS and ESS.

Seung-Beom Lim
../../Resources/kiiee/JIEIE.2025.39.1.22/au3.png

He received Ph.D. degree in electrical engineering from Dankook University in 2014. Since 2007, he has been working on Eon Co., Ltd as a researcher. His research interests are power converters, inverters, UPS and ESS. converters, inverters, UPS and ESS.