References
1
H. C. Miller, “Surface flashover of insulators,” in IEEE Transactions on Electrical Insulation, vol. 24, no. 5, pp. 765-786, 1989.
2
D. K. Davies, “Charge generation on dielectric surfaces,” J. Phys. D: Appl. Phys., vol. 2, no. 11, pp. 1533-1537, 1969.
3
T. Hosokawa, et al., “DC breakdown characteristics in the gap with thin dielectric sheet in air,” in IEEE Transactions on Dielectrics and Electrical Insulation, vol. 18, no. 3, pp. 822-832, 2011.
4
K. Kato, et al., “Influence of surface charges on impulse flashover characteristics of alumina dielectrics in vacuum,” in IEEE Transactions on Dielectrics and Electrical Insulation, vol. 16, no. 6, pp. 1710-1716, 2009.
5
S. -W. Jee and D. -Y. Lim, “Surface discharge mechanism with a change of gas pressure in N2/O2 mixed gas for insulation design of SF6-Free high-voltage power equipment,” in IEEE Transactions on Dielectrics and Electrical Insulation, vol. 28, no. 3, pp. 771-779, 2021.
6
M. Hara, “Particle-initiated breakdown characteristics of conical insulator in N2 gas and N2/O2 mixture under DC voltage,” in IEEE Trans. Electr. Insul., vol. 22, no. 1, pp. 87-96, 1987.
7
D. Y. Lim, S. W. Jee, S. Bae, and Y. K. Choi, “Analysis of the influence of a conductive particle on the surface flashover characteristics of epoxy dielectric in atmospheric air,” J. Electrost., vol. 99, pp. 31-40, 2019.
8
H. C. Miller, “Flashover of insulators in vacuum: the last twenty years,” in IEEE Transactions on Dielectrics and Electrical Insulation, vol. 22, no. 6, pp. 3641-3657, 2015.
9
J. Sun, et al., “A review on surface flashover phenomena at DC voltage in vacuum and compressed gas,” in IEEE Transactions on Dielectrics and Electrical Insulation, vol. 29, no. 1, pp. 1-14, 2022.
10
M. S. Naidu, “Gas Insulated Substations,” I. K. International Publishing House Pvt. Ltd, pp. 123-127, 2008.
11
O. Yamamoto and T. Takuma, “Influence of electric field at cathode triple junction on flashover characteristics in vacuum,” Electrical Engineering in Japan, vol. 131, no. 3, pp. 1-8, 2000.
12
M. Ren, et al., “Partial discharges triggered by metal -particle on insulator surface under standard oscillating impulses in SF6 Gas,” in IEEE Transactions on Dielectrics and Electrical Insulation, vol. 22, no. 5, pp. 3007-3018, 2015.
13
J. T. Krile, A. A. Neuber, J. C. Dickens, and H. G. Krompholz, “DC and pulsed dielectric surface flashover at atmospheric pressure,” in IEEE Transactions on Plasma Science, vol. 33, no. 4, pp. 1149-1154, 2005.